ND-H2

The ND-H2 series uses:

The latest polymer electrolyte membrane (PEM) technology to produce pure hydrogen
A desiccant cartridge which allow to dry the H2 gas and increase the purity

The exclusive, electronically-controlled gas/liquid separator, automatic checking for internal leaks whenever starting the units and constant control of operating parameters, guarantee maximum safety.

The touch screen LCD interface provides simple and user-friendly management of all functions on the unit.

  • Advantages
  • Characteristics
  • Specifications
  • Demo
  • Quote

Advantages

Improved chromatograph result
The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column. Hydrogen as a carrier gas is faster and more sensitive than the more-expensive helium. Run time savings of 25% to 35% without a decline in resolution.

Increased laboratory efficiency
A constant, uninterrupted gas supply of guaranteed purity eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibrations required.

Improved safety
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited.
The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

Simple installation
Gas generators can be installed in the laboratory, on or under a bench, eliminating the need for long gas lines from cylinders secured elsewhere.

Characteristics

  • Patented gas/water separator electronically controlled
  • LCD touch screen : with indication in real time : H2 outlet pressure, H2 flow rate, water quality, water level, cartridge saturation, system status with auto-diagnostics of breakdown with alarms
  • Remote PC monitoring in standard via RS232 and RS485 in option (allow the end user to be connected with the manufacturer for remote diagnostics).
  • Water tank protected and filtered
  • Automatic checking for internal leaks to guarantee maximum safety
  • Automatic internal water tank refill included in standard

Specifications

Models
ND-H2-120
ND-H2-180
ND-H2-260
ND-H2-400
ND-H2-500
General Information
H2 flow rate cc/min
120
180
260
400
500
H2 purity
> 99.9995 % (O2 < 1 ppm, dewpoint H2O < -55°C (-67°F))
Delivery pressure
1 - 10 bar (14 - 145 psi)
H2 dryer
Dessicant cartridge
Internal water tank
2.3 liters with autorefill included
Temperature range
From 5 - 35°C (41 - 95°F) and humidity 80% to 25°C (77°F)
LCD touch screen
Resolution 128 x 64 touch screen with (operating parameters, system status, alarms)
Water quality
Deionised, ASTM II, < 0.1μ
Dimensions (W x H x D)
30 x 43 x 43 cm (12³ x 17³ x 17³)
Outlet port
1/8 Swagelock
Weight (kg/lbs)
14.5 / 32
15.5 / 34
Power consumption
280 W
Power supply
90 - 240 V ac / 50 - 60 Hz
Communication
RS232
X
RS485/USB
Option
X
Special functions
Parallel mode
Option
Automatic internal water tank refill
X

Demo

 

Quote

 